SERIES/MODEL MATERIAL TYPE FRAME DEPTH RATING TEST SIZE DESIGN PRESSURE AIR INFILTRATION WATER RESISTANCE STRUCTURAL OVERLOAD U-Factor SHGC CR STC OITC IMPACT/ BLAST
V200
Project Out
Vinyl 3.25” R-40 48 x 18 60.15 0.03 6.06 60.15 0.23-0.27 -- n/a n/a n/a
C700
Project Out
Aluminum 4.125" AW-PG70 48 x 72 70.18 <0.10 12.11 105.26 0.20-0.32 0.11-0.44 50-79 Contact Quaker Contact QuakerIMPACT
M700
Project Out
Aluminum 3.25” AW-PG70-AP 48 x 72 70 0.06 12.11 70.18 0.43 0.19-0.29 42-49 -- --IMPACT
H450
Project Out
Aluminum 3.25” CW-PG90-AP 60 x 36 90 <0.10 15 135 0.39-0.59 0.14-0.48 57 (Energy Basic) -- --
W600
Project Out
Wood 5.625” AW-PG100* 48 x 72 70.18 <0.10 12.11 105.26 0.17-0.29 0.11-0.44 48-77 Contact Quaker Contact Quaker
V300
Project Out
Vinyl 3.25” CW-50 60 x 32 50 0.01 7.5 75.19 0.23-0.27 0.11-0.27 58 (Energy Basic) 35 29
C600
Project Out
Aluminum 4.125" AW-PG100 60 x 36 150.38 <0.10 15.04 150.38 0.19-0.30 0.11-0.44 50-80 28-41 28-35
M600
Project Out
Aluminum 3.25” AW-PG70-AP 60 x 36 70 <.10 12.11 70.18 0.33-0.55 0.12-0.54 31-46 41-43 33-34
E600
Project Out
Aluminum 3.25” AW-PG70 60 x 36 70 <0.10 12.11 105.26 0.32-0.36 0.10-0.41 56 (Energy Basic) -- --
T600
Project Out
Aluminum 3.25” AW-PG70 60 x 36 70 <0.10 12.11 105.26 0.41-0.45 0.12-0.41 46 (Energy Basic) -- --
Brighton
Project Out
Wood 6” R-50 48 x 24 50 0.05 7.52 75.19 0.28-0.32 0.12-0.28 40-56 -- --
V250
Project Out
Vinyl 3.25” LC-35 36 x 72 50 <0.30 7.52 75.19 0.23 - 0.27 0.12-0.28 -- -- --
V700
Project Out
Vinyl 3.25” CW-50 48 x 32 75.19 0.01 7.5 75.19 0.24-0.28 0.11-0.41 -- -- --IMPACT
H470
Project Out
Aluminum 3.25” CW-80 60 x 36 70 <0.10 12 105 0.39-0.43 0.14-0.45 44-49 -- --IMPACT
H470
Fixed
Aluminum 3.25” AW-PG110-F 60 x 99 70 <0.10 15.04 165.4 0.25-0.31 0.16-0.54 49-61 -- --IMPACT

CASEMENT WINDOWS

SERIES/MODEL MATERIAL TYPE FRAME DEPTH RATING TEST SIZE DESIGN PRESSURE AIR INFILTRATION WATER RESISTANCE STRUCTURAL OVERLOAD U-Factor SHGC CR STC OITC IMPACT/ BLAST
V300
Casement
Vinyl 3.25” CW-50 36 x 78 50 0.01 7.5 75.19 0.23-0.27 0.11-0.27 61 (Energy Basic) -- --
T600
Casement
Aluminum 3.25” AW-PG70 36 x 60 70 < 0.10 12.11 105.26 0.41 - 0.45 0.12-0.41 46 (Energy Basic) -- --
V200
Casement
Vinyl 3.25” R-40 24 x 60 60.15 0.01 6.06 60.15 0.23-0.26 0.12-0.28 -- -- --
C600
Casement
Aluminum 4.125" AW-PG100 36 x 60 150.38 <0.30 15.04 150.38 0.19-0.30 0.11-0.44 51-80 28-41 28-35
C700
Casement
Aluminum 4.125" AW-PG70 48 x 84 70.18 0.02 12.11 105.26 0.20-0.32 0.11-0.44 51-79 28-41 23-34IMPACT
M600
Casement
Aluminum 3.25” AW-PG70-C 36 x 72 70 0.01 12.11 70.18 0.39-0.43 0.19-0.29 45-48 29-38 23-31
M700
Casement
Aluminum 3.25” AW-PG50 (Simulated) 36 x 84 -- 0.01 12.11 50 -- -- -- -- --IMPACT
E600
Casement
Aluminum 3.25” AW-PG70 36 x 72 70 <0.10 12.11 105.26 0.32-0.39 0.12-0.26 56 (Energy Basic) 31-42 25-34
H450
Casement
Aluminum 3.25” CW-PG90-C 36 x 60 90 <0.10 12 105 0.39-0.44 0.14-0.48 -- -- --
W600
Casement
Wood 5.625” AW-PG100* 48 x 84 (Max) 105.26 <0.10 12.11 105.26 0.17-0.28 0.11-0.44 48-77 28-444 28-35
Brighton
Fixed Casement
Wood 6” LC-50 72 x 72 50 <0.01 7.52 75.19 0.25-0.29 0.14-0.33 44-57 -- --
Brighton
Casement
Wood 6” LC-60 36 x 72 60 <0.01 9.19 90.23 0.28-0.32 0.12-0.28 45-58 -- --
V250
Casement
Vinyl 3.25” LC-30 36 x 72 50 0.01 7.52 75 0.23 - 0.26 -- 62 (Energy Basic) -- --
V700
Casement
Vinyl 3.25” CW-50 36 x 78 75.19 0.01 7.5 75.19 0.23-0.27 0.11-0.27 -- -- --IMPACT

DOORS

SERIES/MODEL MATERIAL TYPE FRAME DEPTH RATING TEST SIZE DESIGN PRESSURE AIR INFILTRATION WATER RESISTANCE STRUCTURAL OVERLOAD U-Factor SHGC CR STC OITC IMPACT/ BLAST
V100
Sliding
Vinyl 4.625" R-50 71 x 80 50 n/a 7.50 n/a 0.28-0.29 (with Energy Basic or Energy 3S) -- 58-59 n/a n/a
Brighton
Sliding (French Rail)
Wood 5.938” R-50 -- 50 -- -- -- 0.28 0.17 55 -- --
M600
Sliding
Aluminum 5” AW-PG50-SD 123 x 95 50 <0.01 12.00 75 0.36-0.40 0.21-0.32 44 -- --
Brighton
Sliding (Narrow Rail)
Wood 5.938” R-50 -- 50 -- -- -- 0.25 0.21 55 -- --
M300
Sliding
Aluminum 5” CW-PG50-SD 95 x 83 50 0.16 7.52 75.19 0.34-0.39 0.14-0.50 44 -- --
V250
Sliding
Vinyl 3.25” R-50 72 x 82 -- <0.30 7.52 75.19 0.24-0.30 0.14-0.51 -- -- --
M600
Terrace (Inswing)
Aluminum 4.5” AW-50 48 x 96 50.13 0.05 10.03 50.13 0.35-0.39 0.13-0.43 -- -- --
M600
Terrace (Outswing)
Aluminum 4.5” AW-70 39 x 95 70.18 <0.01 12.11 70.18 0.37-0.42 0.13-0.43 -- 34-38 30-33
M600
Terrace (Outswing w/low profile)
Aluminum 4.5” AW-50 48 x 96 50 0.04 10.03 -- 0.37-0.42 0.13-0.43 -- -- --
Brighton
Hinged (inswing)
Wood 5.938” LC-50 -- 50 -- -- -- 0.28 0.15 61 -- --
Brighton
Hinged (outswing)
Wood 5.938” LC-50 -- 50 -- -- -- 0.23 0.24 -- -- --
V300
Terrace (Inswing)
Vinyl 3.25” CW-50 -- 50* <0.30* Up to 7.52* -- 0.24 - 0.50* -- -- -- --

FIXED WINDOWS

SERIES/MODEL MATERIAL TYPE FRAME DEPTH RATING TEST SIZE DESIGN PRESSURE AIR INFILTRATION WATER RESISTANCE STRUCTURAL OVERLOAD U-Factor SHGC CR STC OITC IMPACT/ BLAST
V100
Fixed
Vinyl 2.75" R-40 60 x 60 40.1 0.01 6.06 n/a 0.29-0.30 (w/Energy Basic or Energy 3s) -- 60-61 (with Low-E/argon) n/a n/a
C600
Fixed
Aluminum 4.125" AW-PG100 72 x 120 120.30 <0.10 12.11 120.30 0.15-0.29 0.13-0.57 51-81 28-41 28-35
B500
Fixed
Aluminum 3.25” HC-50 72 x 72 50 0.1 12 75 -- -- 61 -- --BLAST
E700
Fixed
Aluminum 3.25” HC-40 48 x 90 40 0.03 10.03 60 -- -- 57 (Energy Basic) -- --IMPACT
T500
Fixed
Aluminum 3.25” HC-50 72 x 72 50 0.10 12 75 0.27 - 0.33 0.15-0.36 50 (Energy Basic) -- --
V300
Fixed
Vinyl 3.25” CW-50 60 x 60 50 < 0.30 Up to 7.52 75 As low as 0.23 As low as 0.23 90 -- --
C700
Fixed
Aluminum 4.125" AW-PG70 72 x 120 120.30 <0.10 12.11 120.30 0.15-0.29 0.13-0.57 51-81 28-41 28-35IMPACT
M600
Fixed
Aluminum 3.25” AW-PG70-FW 60 x 60 70 <0.10 12.11 70.18 0.26 0.23-0.36 48-58 32-43 26-33
M700
Fixed
Aluminum 3.25” AW-PG70-F 96 x 60 70 <0.01 12.11 105.26 0.18-0.31 0.13-0.54 48-58 -- --IMPACT
E300
Fixed
Aluminum 3.25” AW-PG50 / CW-70 60 x 99 50 0.01 10 75.19 0.25-0.31 0.16-0.37 57 (Energy Basic) -- --
E500
Fixed
Aluminum 3.25” AW-PG50 / CW-70 60 x 99 70 0.01 10 75.19-105.26 0.25-0.31 0.16-0.37 57 (Energy Basic) -- --BLAST
E600
Fixed
Aluminum 3.25” AW-PG80 60 x 60 80 0.01 12.11 120.30 0.25-0.31 0.15-0.36 54 (Energy Basic) -- --
H450
Fixed
Aluminum 3.25” AW-PG110-F 72 x 120 110 <0.01 15.04 165.4 0.26-0.50 0.16-0.69 -- -- --
H650
Fixed
Aluminum 4.125" AW-PG90 60" x 99" 90 <.10 12 135 -- -- -- -- --
T600
Fixed
Aluminum 3.25” AW-PG70 72 x 120 70 <0.01 12.11 105.27 0.27-0.34 0.15-0.55 55 (Energy Basic) -- --
K200
Fixed
Aluminum 2.375" CW50 64 x 71 60 <0.10 7.52 90.23 0.27-0.32 0.16-0.37 53 (Energy Basic) -- --
W600
Fixed
Wood 5.625” AW-PG80 72 x 120 120.30 <0.10 12.11 120.30 0.14-0.29 0.13-0.57 51-79 28-44 25-35
Brighton
Fixed Casement
Wood 6” LC-50 72 x 72 50 <0.01 7.52 75.19 0.25-0.29 0.14-0.33 44-57 -- --
Brighton
Fixed
Wood 6” R-50 48 x 48 50 <0.01 7.52 75.19 0.23-0.28 0.15-0.37 46-57 -- --
V250
Fixed
Vinyl 3.25” LC-35 56 x 56 50 <0.10 7.52 52.63 0.22-0.28 0.15-0.53 -- -- --
V700
Fixed
Vinyl 3.25” CW-50 60 x 72 50 0.01 7.5 75.19 0.21-0.27 0.15-0.35 -- -- --IMPACT
V200
Fixed
Vinyl 3.25” R-35 48 x 48 -- 0.01 6.06 52.63 0.22-0.28 0.15-0.53 -- -- --
V300
Fixed
Vinyl 3.25” CW-50 78 x 78 50 < 0.30 7.5 75 0.11-0.54 0.21-0.27 46-78 -- --

PROJECT IN WINDOWS

SERIES/MODEL MATERIAL TYPE FRAME DEPTH RATING TEST SIZE DESIGN PRESSURE AIR INFILTRATION WATER RESISTANCE STRUCTURAL OVERLOAD U-Factor SHGC CR STC OITC IMPACT/ BLAST
E600
Project In
Aluminum 3.25” AW-PG70 60 x 36 70 0.03 12.11 105.26 0.32-0.36 0.12-0.26 (with Low-E and Argon) 57 (Energy Basic) -- --
T600
Project In
Aluminum 3.25” AW-PG70 60 x 60 105.26 0.03 12.11 105.26 0.43-0.47 0.12-0.26 43 (Energy Basic) -- --

HORIZONTAL SLIDING WINDOWS

SERIES/MODEL MATERIAL TYPE FRAME DEPTH RATING TEST SIZE DESIGN PRESSURE AIR INFILTRATION WATER RESISTANCE STRUCTURAL OVERLOAD U-Factor SHGC CR STC OITC IMPACT/ BLAST
V100
Slider
Vinyl 2.75" R-40 63 x 44 40.1 0.15 6.06 n/a 0.29-0.30 (with Energy Basic or Energy 3S) -- 60 (with Low-E/argon) n/a n/a
E300
Slider
Aluminum 3.25” CW-PG50 72 x 60 50 0.10 7.52 75.19 0.35 - 0.40 0.14 - 0.31 48 (Energy Basic) -- --
K200
Slider
Aluminum 2.375" CW-PG40 60 x 59 40 0.08 6.06 60.15 0.38 - 0.44 0.14 - 0.33 35 (Energy Basic) 47-51 38 - 39
E700
Slider
Aluminum 3.25” HC-40 -- -- -- -- -- -- -- 50 (Energy Basic) -- --IMPACT
E500
Slider
Aluminum 3.25” AW-PG50 99 x 79 75.19 <0.30 10.03 75.19 0.36-0.41 0.13-48 -- -- --BLAST
V250
Slider
Vinyl 3.25” LC-35 63 x 44 -- 0.01 7.52 75.19 0.24-0.30 0.14-0.50 -- -- --
V200
Slider
Vinyl 3.25” R-40 63 x 44 -- 0.05 6.06 60.15 0.24-0.30 0.14-0.50 -- -- --
V300
Slider
Vinyl 3.25” CW-50 71 x 60 50 <0.30 Up to 7.52 75 As low as 0.25 As low as 0.21 81 -- --

HUNG WINDOWS

SERIES/MODEL MATERIAL TYPE FRAME DEPTH RATING TEST SIZE DESIGN PRESSURE AIR INFILTRATION WATER RESISTANCE STRUCTURAL OVERLOAD U-Factor SHGC CR STC OITC IMPACT/ BLAST
V100
Single Hung
Vinyl 2.75" R-40 40" x 63" 40.1 0.09 6.06 -- 0.30 (with Low-E/argon) -- 59-60 (with Low-E/argon) n/a --
V200
Single Hung
Vinyl 3.25” R-35 40 x 63 52.63 0.1 5.43 60.15 025-0.29 0.14-0.33 -- -- --
H650
Single Hung
Aluminum 4.125" AW-PG60-H 60 x 99 60 <0.30 12 90 as low as 0.30 -- -- -- --
E500
Single Hung
Aluminum 3.25” AW-PG40 60 x 99 40 0.25 8.15 60.15 0.37 - 0.42 0.13-0.46 -- -- --
B500
Single Hung
Aluminum 3.25” AW-PG50 60 x 99 50 0.03 10.03 75.19 -- -- 40 (Energy Basic) -- --BLAST
E300
Single Hung
Aluminum 3.25” CW-PG50 56 x 91 50 0.05 7.52 75.19 0.35 - 0.40 0.13 - 0.30 -- -- --
T500
Single Hung
Aluminum 3.25” AW-PG50 60 x 99 50 0.03 10 75.19 0.37 - 0.42 0.14-0.33 40 (Energy Basic) -- --
K200
Single Hung
Aluminum 2.375" C50 54 x 90 50 0.10 7.5 75 0.38-0.45 0.14 - 0.32 -- -- --
Brighton
Single Hung
Wood 6” R-50 36 x 84 50 0.04 7.52 75.19 0.28-0.32 0.12-0.29 44-55 -- --
V250
Single Hung
Vinyl 3.25” LC-35 36 x 84 -- <0.30 7.52 75 0.25-0.30 0.14-0.51 58 (Energy Basic) -- --
V300
Single Hung
Vinyl 3.25” CW-50 44 x 78 50 <0.30 Up to 7.52 75 As low as 0.25 As low as 0.21 81 -- --
V200
Double Hung
Vinyl 3.25” R-40 40 x 63 60.15 0.16 7.52 60.15 0.25-0.29 0.14-0.32 -- -- --
E500
Double Hung
Aluminum 3.25” AW-PG40 60 x 99 40 0.25 8.15 60.15 0.37 - 0.42 (with Low-E and Argon) 0.13 - 0.46 (with Low-E and Argon) 51 (Energy Basic) -- --
E300
Double Hung
Aluminum 3.25” CW-PG50 47 x 59 50 0.05 7.52 75.19 0.35 - 0.40 0.13 - 0.30 50 (Energy Basic) 28-36 23-31
K200
Double Hung
Aluminum 2.375" C50 54 x 90 50 0.10 7.5 75 0.35-0.45 0.14 - 0.32 39 (Energy Basic) -- --
Brighton
Double Hung
Wood 6” R-50 36 x 84 50 0.04 7.52 75.19 0.28-0.32 0.12-0.29 44-55 -- --
V250
Double Hung
Vinyl 3.25” LC-35 36 x 84 -- <0.30 7.52 75 0.25-0.30 0.14-0.50 58 (Energy Basic) -- --